Title: Seismic response of precast structures with vertical cladding panels: the SAFECLADDING experimental campaign
Authors: NEGRO PaoloLAMPERTI TORNAGHI MARCO
Citation: ENGINEERING STRUCTURES vol. 132 p. 205–228
Publisher: ELSEVIER SCI LTD
Publication Year: 2017
JRC N°: JRC103551
ISSN: 0141-0296
URI: http://www.sciencedirect.com/science/article/pii/S0141029616312196
http://publications.jrc.ec.europa.eu/repository/handle/JRC103551
DOI: 10.1016/j.engstruct.2016.11.020
Type: Articles in periodicals and books
Abstract: The SAFECLADDING Project was aimed at improving the connection systems between cladding panels and precast RC buildings in seismic-prone areas. Three design criteria have been assessed: isostatic, dissipative and integrated. They can be realised using different design strategies, which are represented by several test setups within the experimental campaign. The paper describes the results obtained with vertical panels arrangement and the comparison with the bare frame, which is the reference for the current design practice that considers panels like non-structural elements. The mock-up and the test sequence were designed to assess all setups with a single frame structure. The mock-up was a one-storey building, made by two parallel frames with two bays and square columns, inserted into pocket plinths. The building was designed for earthquake actions according to the Eurocode 8. Each setup was assessed using increasing levels of action, either with cyclic or pseudo-dynamic tests. The latter were performed both for serviceability and ultimate limit states. The experimental programme for vertical-panels and the bare-frame arrangement involved ten different setups, resulting in a total of twenty-eight tests. As for the isostatic criterion, the results confirm that considering panels as simple masses without stiffness is far from the real system behaviour, even using apposite devices to uncouple panels and frame displacements. In fact, despite a previous and positive experimental qualification, several devices failed in operative conditions tests. Conversely, the integrated criterion requires to bear high loads, transferred by the frame through connections, which becomes the weak point for this configuration, as demonstrated by different failures of bolts and connections. The reliability of the dissipative criterion has been confirmed by twelve tests completed without any damage. This solution in fact combines lower relative displacements with limited loads within connections, avoiding both the compatibility problems and excessive forces.
JRC Directorate:Space, Security and Migration

Files in This Item:
There are no files associated with this item.


Items in repository are protected by copyright, with all rights reserved, unless otherwise indicated.