Title: Spatial distribution of uranium isotopes in solid nuclear materials using laser ablation multi-collector ICP-MS
Authors: KRACHLER MICHAELVARGA ZSOLTNICHOLL ADRIANWALLENIUS MARIAMAYER KLAUS
Citation: MICROCHEMICAL JOURNAL vol. 140 p. 24-30
Publisher: ELSEVIER SCIENCE BV
Publication Year: 2018
JRC N°: JRC110941
ISSN: 0026-265X
URI: http://publications.jrc.ec.europa.eu/repository/handle/JRC110941
DOI: 10.1016/j.microc.2018.03.038
Type: Articles in periodicals and books
Abstract: Employing laser ablation multi-collector ICP-MS (LA-MC-ICP-MS), its potential for evaluating the homogeneity of solid uranium (U) bearing materials was investigated. To this end, the n(235U)/n(238U) ratio of two low-enriched U certified reference materials (CRMs), i.e. powdered standard reference material U-010 (~1 wt.-% 235U) and a UO2 pellet of CRM 125-A (~4 wt.-% 235U) was determined using line scan analysis. Four spots of 5 µm diameter each were ablated per second with the LA system moved at a speed of 20 µm s-1 for several minutes. Experimental and certified U isotope ratios matched perfectly, unequivocally validating the accuracy of the applied analytical methodology. In addition, the narrow and symmetric frequency distribution of the n(235U)/n(238U) ratio of both CRMs confirmed their homogeneity with respect to the U isotopic composition. Utilizing LA-MC-ICP-MS line scan analysis of two similar UO2 pellets (~1 wt.-% 235U) from the 5th Collaborative Materials Exercise (CMX-5) revealed diverse inhomogeneity regarding their n(235U)/n(238U) ratio. Although both UO2 pellets used for the CMX-5 exercise were prepared from identical source materials, their different production routes yielded largely contrasting frequency distributions of the n(235U)/n(238U) ratio. While 235U isotope abundance ranged from 0.75%-1.6% for the first pellet, this value fluctuated between 0.45% and 3.0% for the second pellet. This specific information sheds additional light on the production process of these materials and is helpful in nuclear forensics investigations when determining the origin of unknown nuclear material. The depleted nature (~0.4 wt.-% 235U) of two seized U metal samples was established through LA-MC-ICP-MS analysis of the n(235U)/n(238U) ratio. As black and yellow regions within both U bearing samples had identical U isotopic composition, the observed colour differences might arise from different degrees of U oxidation and are not associated with U isotopic inhomogeneity within the material. The significantly different 235U abundance of the two samples (0.3670±0.0015 wt.-% and 0.4146±0.0013 wt.-%), however, clearly indicates they were prepared from different source materials and/or from diverse amounts of them.
JRC Directorate:Nuclear Safety and Security

Files in This Item:
There are no files associated with this item.


Items in repository are protected by copyright, with all rights reserved, unless otherwise indicated.