Title: Certification of Charpy V-notch Reference Test Pieces of 30 J Nominal Absorbed Energy, ERM-FA013az
Authors: ROEBBEN GERTLAMBERTY ANDREE
Publisher: OPOCE
Publication Year: 2008
JRC N°: JRC45470
ISBN: 978-92-79-09022-6
ISSN: 1018-5593
Other Identifiers: EUR 23369 EN
OPOCE LA-NA-23369-EN-C
URI: http://publications.jrc.ec.europa.eu/repository/handle/JRC45470
DOI: 10.2787/41130
Type: EUR - Scientific and Technical Research Reports
Abstract: This certification report describes the processing and characterisation of ERM-FA013az, a batch of Charpy V-notch certified reference test pieces. Sets of five of these test pieces are used for the verification of pendulum impact test machines according to EN 10045-2 or according to ISO 148-2. The certified value for KV (absorbed energy = energy required to break a V-notched test piece using a pendulum impact test machine) is 27.2 J. The associated expanded uncertainty (0.9 J, k = 2 corresponding to a confidence level of about 95 %) is calculated for the mean of a set of five test pieces. The certified value is traceable to the Charpy impact test method as described in EN 10045 1 (3) and ISO 148 (4), via the corresponding Master Batch ERM-FA013d of the same nominal absorbed energy (30 J).
JRC Institute:Institute for Reference Materials and Measurements

Files in This Item:
File Description SizeFormat 
108-2008_as published.pdf827.8 kBAdobe PDFView/Open