Title: Preparation and Certification of IRMM-3636, IRMM-3636a and IRMM-3636b
Authors: VERBRUGGEN ANDREALONSO-MUNOZ AdolfoEYKENS ROGERKEHOE FRANCESKUEHN HEINZRICHTER STEPHANAREGBE YETUNDE
Publisher: OPOCE
Publication Year: 2008
JRC N°: JRC45903
ISBN: 978-92-79-09381-4
ISSN: 1018-5593
Other Identifiers: EUR 23408 EN
OPOCE LA-NA-23408-EN-C
URI: http://publications.jrc.ec.europa.eu/repository/handle/JRC45903
DOI: 10.2787/60083
Type: EUR - Scientific and Technical Research Reports
Abstract: Isotope reference materials IRMM-3636 was prepared by gravimetrically mixing of solutions from highly enriched 99.96% 233U (IRMM-3630) and highly enriched 99.97% 236U (IRMM-3660) in order to obtain an isotopic ratio n(233U)/n(236U) close to unity. IRMM-3636a and IRMM-3636b were prepared from IRMM-3636 by gravimetrical dilution. The primary solution, IRMM-3636 is for the time being not yet available for external users. The certified isotope content values for IRMM-3636a of 4.27988(54)*10-7 mol U per g of solution and for IRMM-3636b of 2.21802(61)*10-8 mol U per g of solution and the certified isotope amount ratios have been established by mass metrology, subsequently the primary solution IRMM-3636 was verified by isotope mass spectrometry. The methodology used in the preparation and certification was similar to that of comparable uranium mixtures made in the past. The uncertainties contributing to the final uncertainties of the isotopic ratios are the weighing errors, the measured impurities in each starting material, the stoichiometry of the oxides and the isotopic abundances of each of the starting materials. The method for the preparation and mixing is described and the certification and verification procedures are reported. Verification of IRMM-3636 was performed by TRITON TIMS measurements using Faraday collectors and secondary electron multiplier in combination with an RPQ energy filter for improved abundance sensitivity. The results agreed well with the certified values obtained from the mixing calculations. By mixing the n(233U)/n(236U) double spike with a sample and applying internal mass fractionation correction, the n(235U)/n(238U) ratio of a given sample can be determined with the highest possible accuracy. The Isotopic Reference Materials IRMM-3636, IRMM-3636a and IRMM-3636b are part of a systematic IRMM programme to supply Isotopic Reference Materials of various isotopes at different concentrations. The Isotopic Reference Material is supplied in a sealed quartz ampoule containing 1 mL of a 1 M nitric acid solution.
JRC Institute:Institute for Reference Materials and Measurements

Files in This Item:
File Description SizeFormat 
reqno_jrc45903_jrc23408_preparation_and_certification_of_irmm-3636.pdf[1].pdf1.5 MBAdobe PDFView/Open


Items in repository are protected by copyright, with all rights reserved, unless otherwise indicated.