Title: Report of the interlaboratory comparison organized by the Community Reference Laboratory Food Contact Material: Plasticisers in Gaskets and Oil
Authors: BRATINOVA StefankaVALZACCHI SandroBELDI GiorgiaMORKUNAS VaidasCONTINI ClaudiaHANNAERT PhilippeSIMONEAU Catherine
Publisher: European Commission
Publication Year: 2009
JRC Publication N°: JRC53243
ISBN: 978-92-79-13159-2
ISSN: 1018-5593
Other Identifiers: EUR 23972 EN
OPOCE LB-NA-23-972-EN-C
URI: http://publications.jrc.ec.europa.eu/repository/handle/JRC53243
DOI: 10.2788/29683
Type: EUR - Scientific and Technical Research Reports
Abstract: The Institute for Health and Consumer Protection (IHCP) of the European Commission¿s Directorate-General Joint Research Centre hosts the Community Reference Laboratory for Food Contact Materials (CRL-FCM). One of its core tasks is to organize interlaboratory comparisons (ILCs) among appointed National Reference Laboratories (NRLs). This report presents the results of the first ILC of the CRL-FCM which focused on the determination of Plasticisers content in PVC Gasket and in Oil matrix. The test materials used in this exercise were virgin gasket lids coming from industrial sources for the proficiency exercise part A. For the second part of the exercise an industrial source of sunflower oil was used and spiked with several plasticisers by the CRL-FCM. There were 41 participants to whom samples were dispatched 34 of which submitted results for at least 1 analyte-material. 21 laboratories reported results for more than 10 analyte-material combination out of 14 required. The homogeneity studies were performed by the CRL-FCM laboratory. The assigned value and its uncertainty for part A, virgin gaskets, were obtained after applying the robust statistics to the results obtained from the participants. The assigned values for part B, oil samples, were those obtained based on formulation, from the gravimetric measurements used to spike the material. The uncertainty of the assigned values for oil samples was calculated combining the uncertainty of the spiking procedure with a contribution for the between-bottle homogeneity. Participants were invited to report four replicates measurements. This was done by most of the participants. Laboratory results were rated with z and z¿ scores in accordance with ISO 13528 [1] Standard deviations for proficiency assessment (also called target standard deviations) were set based on Horwitz equation for substances in the two oil samples. For the plasticisers in the two gasket samples the target standard deviation was set by the organizers to 15% in order to fulfil the required criteria for sufficient homogeneity of the sample within the lots.
JRC Institute:Institute for Health and Consumer Protection

Files in This Item:
File Description SizeFormat 
crl_fcm_pt001_final_report_eur 2009_10_20.pdf5.83 MBAdobe PDFView/Open


Items in repository are protected by copyright, with all rights reserved, unless otherwise indicated.