Title: Report of laboratory and in-situ validation of micro-sensor for monitoring ambient air - Ozone micro-sensors, αSense, model B4 O3 sensors
Publisher: Publications Office of the European Union
Publication Year: 2014
JRC N°: JRC90463
ISBN: 978-92-79-38538-4
ISSN: 1831-9424
Other Identifiers: EUR 26681
OP LB-NA-26681-EN-N
URI: http://publications.jrc.ec.europa.eu/repository/handle/JRC90463
DOI: 10.2788/84725
Type: EUR - Scientific and Technical Research Reports
Abstract: The aim of this report was to evaluate and validate O3-B4 sensors of αSense within laboratory and field tests under ambient/indoor air conditions corresponding to a specific micro-environment: traffic station, urban/suburban areas. This report presents the evaluation of the performances and determination of the laboratory and field measurement uncertainty of the sensor values, compared to uncertainties fixed by the Data Quality Objective (DQO) of the European Air Quality Directive for indicative method. Further, procedures for the calibration of sensors able to ensure full traceability of measurements of sensors to SI units are developed.
JRC Institute:Sustainable Resources

Files in This Item:
File Description SizeFormat 
lb-na-26681-en-n.pdf9.7 MBAdobe PDFView/Open

Items in repository are protected by copyright, with all rights reserved, unless otherwise indicated.