Title: Angular-Resolution and Material-Characterization Measurements for a Dual-Particle Imaging System with Mixed-Oxide Fuel
Authors: POITRASSON-RIVIERE AlexisPOLACK KHAMEL MichaelKLEMM DietrichITO KaiALEXANDER McspadenFLASKA MarekCLARKE Shaun D.POZZI SaraTOMANIN ALICEPEERANI Paolo
Citation: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT vol. 797 p. 278-284
Publisher: ELSEVIER SCIENCE BV
Publication Year: 2015
JRC N°: JRC96190
ISSN: 0168-9002
URI: http://www.sciencedirect.com/science/article/pii/S0168900215007950
http://dx.doi.org/10.1016/j.nima.2015.06.045
http://publications.jrc.ec.europa.eu/repository/handle/JRC96190
DOI: 10.1016/j.nima.2015.06.045
Type: Articles in periodicals and books
Abstract: A dual-particle imaging (DPI) system, capable of simultaneously imaging fast neutrons and gamma rays, has been operated in the presence of mixed-oxide (MOX) fuel to assess the system’s angular resolution and material-characterization capabilities. The detection principle is based on the scattering physics of neutrons (elastic scattering) and gamma rays (Compton scattering) in organic and inorganic scintillators. The detection system is designed as a combination of a two-plane Compton camera and a neutron-scatter camera. The front plane consists of EJ-309 liquid scintillators and the back plane consists of interleaved EJ-309 and NaI(Tl) scintillators. MCNPX-PoliMi was used to optimize the geometry of the system and the resulting prototype was built and tested using a Cf-252 source as an SNM surrogate. A software package was developed to acquire and process data in real time. The software was used for a measurement campaign to assess the angular resolution of the imaging system with MOX samples. Measurements of two MOX canisters of similar isotopics and intensity were performed for 6 different canister separations (from 5° to 30°, corresponding to distances of 21 cm and 131 cm, respectively). The measurements yielded a minimum separation of 20° at 2.5 m (86-cm separation) required to see 2 separate hot spots. Additionally, the results displayed good agreement with MCNPX-PoliMi simulations. These results indicate an angular resolution between 15° and 20°, given the 5° step. Coupled with its large field of view, and its capability to differentiate between spontaneous fission and (,n) sources, the DPI system shows its potential for nuclear-nonproliferation applications.
JRC Directorate:Nuclear Safety and Security

Files in This Item:
There are no files associated with this item.


Items in repository are protected by copyright, with all rights reserved, unless otherwise indicated.