Title: Silver nanoparticles and metallic silver interfere with the Griess Reaction: reduction of the azo-dye formation via a competing Sandmeyer-like reaction
Authors: KAEMPFER ANGELALA SPINA RITAGILLILAND DOUGLASVALZACCHI SANDROASTURIOL BOFILL DAVIDSTONE VICKIKINSNER-OVASKAINEN AGNIESZKA
Citation: CHEMICAL RESEARCH IN TOXICOLOGY vol. 30 no. 4 p. 1030-1037
Publisher: AMER CHEMICAL SOC
Publication Year: 2017
JRC N°: JRC101481
ISSN: 0893-228X
URI: http://pubs.acs.org/doi/abs/10.1021/acs.chemrestox.6b00280
http://publications.jrc.ec.europa.eu/repository/handle/JRC101481
DOI: 10.1021/acs.chemrestox.6b00280
Type: Articles in periodicals and books
Abstract: Silver (Ag) is the most common nanomaterial (NM) in consumer products. Much research has been focused on elucidating the potential impact of Ag-containing NMs on human health, e.g., cytotoxicity, genotoxicity, or proinflammatory responses. In the case of proinflammatory responses, a frequently used end point is the induction of nitric oxide (NO), which is indirectly quantified as nitrite (NO2-) with the Griess reaction. After preliminary studies in a macrophage-like cell culture system showed anomalous false negative results in the presence of silver nanoparticles (Ag NPs), we studied the influence of Ag on the detection of NO2- in a cell-free environment. Solutions containing a known concentration of NaNO2 were prepared in H2O, PBS, or complete cell culture medium (CCM) and analyzed using the Griess reaction in the presence of Ag in its metallic or ionic state. In Milli-Q H2O, the impact of salts on the detection was investigated using NaCl and KBr. After completion of the Griess reaction, the samples were analyzed spectrophotometrically or chromatographically. It was found that the presence of metallic but not ionic Ag interfered with the quantification of NO2-. The effect was more pronounced in PBS and H2O containing NaCl or KBr. The chromatographical analysis provided evidence of a competing reaction consuming the intermediate diazonium salt, which is critical to the Griess reaction. These findings demonstrate yet another substantial interference of NMs with a frequently used in vitro assay. If gone unnoticed, this interference might cause false negative results and an impaired hazard assessment of Ag NMs.
JRC Directorate:Health, Consumers and Reference Materials

Files in This Item:
There are no files associated with this item.


Items in repository are protected by copyright, with all rights reserved, unless otherwise indicated.