Fast charging diversity impact on total harmonic distortion due to phase cancellation effect: Fast Charger's testing experimental results
Full charging cycles were performed in the studied chargers and THDV and THDI were observed. From the measurements it can be observed that the phase angles vary within a preferential range, i.e. remain within a range which is actually <90˚of amplitude. Two of the Chargers, working individually, failed to comply with the standards. Charger A barely makes it in terms of TDD and Charger C is out of the limit. In terms of
individual harmonics also Charger A and Charger C are out of the limit of 4.5% for the 11th and 13th harmonics. The next step of the research will be to obtain the statistical distribution of each of the phase angles for all Chargers and perform simulations with different scenarios. Results so far suggest that stand alone Chargers with low short circuit values are recommended to have filters <13% THD.
ROCHA PINTO LUCAS Alexandre;
2017-01-23
Publications Office of the European Union
JRC104793
978-92-79-65399-5,
1831-9424,
EUR 28438 EN,
OP KJ-NA-28438-EN-N,
https://publications.jrc.ec.europa.eu/repository/handle/JRC104793,
10.2760/12246,
Additional supporting files
| File name | Description | File type | |