Development and test of the high-precision gamma-beam monitor at the ESFRI facility ELI-NP
This document describes the development of a fission chamber for gamma beam intensity monitoring at the high-energy gamma line at ELI-NP.
The fission chamber foreseen for monitoring the gamma beam intensity on the high-energy beam line at ELI-NP is an ionization chamber with several 238U deposits of a thickness in the range from 100 to 150 μg/cm2 in a compact design. The innovative design of the chamber allows measuring for each individual micro pulse arriving at a time interval of 1.6x10^-8 s.
GÖÖK Alf;
OBERSTEDT Stephan;
GEERTS Wouter;
HAMBSCH Franz-Josef;
2018-01-03
Publications Office of the European Union
JRC109694
978-92-79-77287-0,
1831-9424,
EUR 29002 EN,
OP KJ-NA-29002-EN-N,
https://publications.jrc.ec.europa.eu/repository/handle/JRC109694,
10.2760/367216,