Case study on the impact of cogeneration and thermal storage on the flexibility of the power system
This work investigates the optimal operation of cogeneration plants combined with thermal storage. To do so, a combined heat and power (CHP) plant model is formulated and incorporated into Dispa-SET, a JRC in-house unit commitment and dispatch model. The cogeneration model sets technical feasible operational regions for different heat uses defined by temperature requirements.
KAVVADIAS Konstantinos;
JIMENEZ NAVARRO Juan Pablo;
ZUCKER Andreas;
QUOILIN Sylvain;
2018-02-06
Publications Office of the European Union
JRC110285
978-92-79-77808-7,
1831-9424,
EUR 29082 EN,
OP KJ-NA-29082-EN-N,
https://publications.jrc.ec.europa.eu/repository/handle/JRC110285,
10.2760/814708,
Additional supporting files
| File name | Description | File type | |