Fracture Toughness Calibration of the Si3N4/Fe Joint System. A Parametric Study
Fracture toughness calibration of the Si3N4/Fe joint system has been performed for various mixed mode loading conditions and for different thickness of the metal interlayer. The asymmetric four point bend loading geometry was used. the values for the calibration function Y as well as the mode mixing of the system increase by increasing the thickness of the metal. As the loading conditions change from mode II to mode I the dependence of both parameters on metal thickness is more intensive.
STAMOS Vassilis;
PETEVES Stathis Dimitris;
KOSTOPOULOS Vassilis;
1995-09-28