European Commission harmonisation programme for Air Quality Measurements
Within the harmonisation programme of air-quality monitoring in Europe, as required by European air policy, the European Reference Laboratory of Air Pollution (ERLAP) organises proficiency tests (PTs) for inorganic gaseous air pollutants for the National air quality reference laboratories. This report evaluates the proficiency of participating laboratories for SO2, CO, O3, NO and NO2 using the z or z’ score and En score performance indicators. Based on the z or z’ score evaluation, 99.1% of the reported results were satisfactory. Considering the En score, 93.5% of the reported values were satisfactory. These results are in line with previous exercises. The En score calculation uses the expanded uncertainty of the assigned value provided by the ERLAP that includes the contribution as well from homogeneity of the test-gas.
BARBIERE Maurizio Giuseppe;
TARRICONE Claudia;
BOROWIAK Annette;
2026-10-09
Publications Office of the European Union
JRC148018
978-92-68-42723-1 (online),
1831-9424 (online),
EUR 40830,
OP KJ-01-26-361-EN-N (online),
https://publications.jrc.ec.europa.eu/repository/handle/JRC148018,
10.2760/0283136 (online),
| Name | Country | City | Type |
|---|
This document is only visible at the Commission level.
You are not authorized to publish or distribute it outside the European Commission.
This is a public document. You can share this publication.
Datasets
| ID | Title | Public URL |
|---|
Dataset collections
| ID | Acronym | Title | Public URL |
|---|
Scripts / source codes
| Description | Public URL |
|---|
Additional supporting files
| File name | Description | File type |
|---|