Full metadata record
DC FieldValueLanguage
dc.contributor.authorBOURVA L.c.-a.en_GB
dc.contributor.authorCROFT S.en_GB
dc.contributor.authorOTTMAR Herberten_GB
dc.contributor.authorWEAVER D.r.en_GB
dc.date.accessioned2010-02-25T14:50:55Z-
dc.date.available1998-11-17en_GB
dc.date.available2010-02-25T14:50:55Z-
dc.date.issued1999en_GB
dc.date.submitted1998-07-01en_GB
dc.identifier.citationNuclear Instruments & Methods in Physics Research Part A vol. 426 p. 503-517en_GB
dc.identifier.urihttp://publications.jrc.ec.europa.eu/repository/handle/JRC16823-
dc.description.abstractA series of Monte Carlo neutron calculations for a combined gamma/passive neutron coincidence counter has been performed. This type of detector, part of a suite of non-destructive assay instruments utilised for the enforcement of the Euratom nuclear safeguards within the European Union, is to be used for high accuracy measurements of the plutonium content of nuclear materials. The multi-purpose Monte Carlo N-Particle (MCNP) code version 4B has been used to model in detail the neutron coincidence detector and to investigate the leakage self-multiplication of PuO2 and Mixed U-Pu Oxide (MOX) reference samples used to calibrate the instrument. The MCNP calculations have been used together with a neutron coincidence counting interpretative model to determine characteristic parameters of the detector. A comparative study to both experimental and previous numerical results has been performed. Sensitivity curves of the variation of the detector's efficiency, epsilon, to the (alpha,n), to spontaneous fission neutron emission rate ratio, alpha, and to the reals coincidence gate utilisation factor, fr, are presented. Once bias-corrected, the trends of the real coincidence counts rate as a function of sample mass for three types of sample could be matched within 0.33% of experimental results. This result confirms the possible use of MCNP to calculate response trends accurately for a wide variety of source materials, given a limited experimental calibration set. Sources of the inaccuracy in the calculations have not yet been fully investigated, because of the vast parameter space to be investigated, but values of the coincidence gate utilisation factor derived directly from the MCNP data have been found to be overestimated by about 8.2%.en_GB
dc.description.sponsorshipJRC.E-Institute for Transuranium Elements (Karlsruhe)en_GB
dc.format.mediumPrinteden_GB
dc.languageENGen_GB
dc.relation.ispartofseriesJRC16823en_GB
dc.titleMCNP Modelling of a combindes Neutron/Gamma Counter.en_GB
dc.typeArticles in periodicals and booksen_GB
JRC Directorate:Nuclear Safety and Security

Files in This Item:
There are no files associated with this item.


Items in repository are protected by copyright, with all rights reserved, unless otherwise indicated.