Certification of Charpy V-notch Reference Test Pieces of 80 J Nominal Absorbed Energy, ERM®-FA015u
This certification report describes the processing and characterisation of ERM®-FA015u, a batch of Charpy V-notch certified reference test pieces. Sets of five of these test pieces are used for the verification of pendulum impact test machines according to EN 10045-2 or according to ISO 148-2. The certified value for KV (=energy required to break a V-notched test piece using a pendulum impact test machine) is 79.8 J. The associated uncertainty (2.4 J, k = 2 corresponding to a confidence level of 95 %) is calculated for the mean of a set of five test pieces. The certified value is traceable to the Charpy impact test method as described in EN 10045 1 (3) and ISO 148 (4), via the corresponding Master Batch ERM®-FA015o of the same nominal absorbed energy (80 J).
ROEBBEN Gert;
LAMBERTY Andree;
2008-02-27
OPOCE
JRC43685
978-92-79-08447-8,
1018-5593,
EUR 23263 EN,
OP LA-NA-23263-EN-C,
https://publications.jrc.ec.europa.eu/repository/handle/JRC43685,
10.2787/32678,
Additional supporting files
| File name | Description | File type | |