Full metadata record
DC FieldValueLanguage
dc.contributor.authorLIU Yuan-Haoen_GB
dc.contributor.authorNIEVAART Victor Alexanderen_GB
dc.contributor.authorTSAI Pi-Enen_GB
dc.contributor.authorLIU Hong-Mingen_GB
dc.contributor.authorMOSS Raymonden_GB
dc.contributor.authorJIANG Shiang-Hueien_GB
dc.date.accessioned2010-02-25T15:55:37Z-
dc.date.available2009-01-29en_GB
dc.date.available2010-02-25T15:55:37Z-
dc.date.created2009-01-26en_GB
dc.date.issued2008en_GB
dc.date.submitted2008-10-23en_GB
dc.identifier.citationProceedings of the 13th International Congress on Neutron Capture Therapy, ISBN: 88-8286-167-8 p. 661-664en_GB
dc.identifier.urihttp://publications.jrc.ec.europa.eu/repository/handle/JRC48382-
dc.description.abstractThis paper aims to measure the spectra of HB11 (HFR) and the THOR BNCT beams by multiple activation foils. The self-shielding corrections were made with the aid of MCNP calculations. The initial spectra were adjusted by a sophisticated process named coarse-scaling adjustment using SAND-EX, which can adjust a given coarse-group spectrum into a fine-group structure, i.e. 640 groups, with excellent continuity. The epithermal neutron flux of the THOR beam is about three times of HB11. The thermal neutron flux, boron and gold reaction rates along the central axis of a PMMA phantom are calculated for both adjusted spectra for comparison.en_GB
dc.description.sponsorshipJRC.F.4-Safety of future nuclear reactorsen_GB
dc.format.mediumPrinteden_GB
dc.languageENGen_GB
dc.publisherENEAen_GB
dc.relation.ispartofseriesJRC48382en_GB
dc.titleNeutron Spectra Measurement and Comparison of the HFR and THOR BNCT Beamsen_GB