Full metadata record
DC FieldValueLanguage
dc.contributor.authorUMLAUF Guntheren_GB
dc.contributor.authorCHRISTOPH Helmut Eugenen_GB
dc.contributor.authorMARIANI Giulioen_GB
dc.contributor.authorEISENREICH Stevenen_GB
dc.contributor.authorPARADIZ Bostjanen_GB
dc.contributor.authorVIVES RUBIO Ingriden_GB
dc.date.accessioned2012-04-17T20:02:34Z-
dc.date.available2010-01-27en_GB
dc.date.available2012-04-17T20:02:34Z-
dc.date.created2010-01-26en_GB
dc.date.issued2010en_GB
dc.date.submitted2008-11-04en_GB
dc.identifier.citationENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH vol. 17 no. 2 p. 462-469en_GB
dc.identifier.issn0944-1344en_GB
dc.identifier.urihttp://publications.jrc.ec.europa.eu/repository/handle/JRC48544-
dc.description.abstractPurpose: The aim of the study was to identify the impact PCDD/F emission sources on ambient air concentrations in Malopolska Region, southern Poland. Three sites were selected: city center of Krakow (Aleje), an industrial area (Nova Huta) and a rural site (Zakopane). In order to investigate the annual variations of PCDD/F sources, summer and winter time samples were taken. Sampling and analytical methods: Ambient air particulate matter (PM10) was collected using an Anderson High Volume sampler during June and December 2002 in the three mentioned sites. Analysis of PCDD/Fs was based on isotope dilution using high resolution gas chromatography-high resolution mass spectrometry (HRGC-HRMS) for quantification. Results: Total concentrations of 2,3,7,8-PCDD/Fs in air particulate phase from Malopolska region ranged from 0.6 to 37 pg m-3 (0.04-3.2 pg WHO98-TEQ m-3, 0.037-2.9 pg I-TEQ m-3). Higher PCDD/F concentrations were measured at all three sites during winter. A linear correlation among PCDD/F concentrations, B(a)P and PM10 concentrations was found in Aleje and Zakopane, which suggested that all compounds were originating from the same source, solid fuel domestic heating. Instead, PCDD/F levels in Nova Huta did not correlate with the seasonality of B(a)P or PM10 levels and 2,3,7,8-PCDD/F congener patterns for this site were significantly different from the other sites. Conclusions: Domestic solid fuel combustion is likely the main PCDD/F source in winter in this part of Poland for urban and rural sites. PCDD/F fingerprints in the industrial site remained almost identical during summer and winter, confirming the yearly prevalence of the emissions from the nearby metal industry.en_GB
dc.description.sponsorshipJRC.H.1-Water Resourcesen_GB
dc.format.mediumPrinteden_GB
dc.languageENGen_GB
dc.publisherSPRINGER HEIDELBERGen_GB
dc.relation.ispartofseriesJRC48544en_GB
dc.titleSeasonality of PCDD/Fs in Ambient Air of Malopolska Region, Southern Polanden_GB
dc.typeArticles in periodicals and booksen_GB
dc.identifier.doi10.1007/s11356-009-0215-4en_GB
JRC Directorate:Sustainable Resources

Files in This Item:
There are no files associated with this item.


Items in repository are protected by copyright, with all rights reserved, unless otherwise indicated.