A careful evaluation of uranium enrichment measurements
with a 2¿ x 2¿ LaBr3(Ce) scintillation detector
has been carried out in order to test this new
type of detector as a room-temperature detector
option for future use in the in-field analyses made
with COMPUCEA. Spectrum analysis has been
made with an adapted version of the NaIGEM analysis
code. Comparative performance data obtained
from measurements with HPGe, NaI(Tl) and LaBr3(Ce)
detectors on low-enriched uranium reference samples
are presented.