DC FieldValueLanguage
dc.contributor.authorLEPY M.-C.en_GB
dc.contributor.authorALTZITZOGLOU Timotheosen_GB
dc.contributor.authorANAGNOSTAKIS M.j.en_GB
dc.contributor.authorARNOLD D.en_GB
dc.contributor.authorCAPOGNI M.en_GB
dc.contributor.authorCECCATELLI A.en_GB
dc.contributor.authorDE FELICE P.en_GB
dc.contributor.authorDERSCH Raineren_GB
dc.contributor.authorDRYAK P.en_GB
dc.contributor.authorFAZIO A.en_GB
dc.contributor.authorFERREUX L.en_GB
dc.contributor.authorGUARDATI M.en_GB
dc.contributor.authorHAN J.en_GB
dc.contributor.authorHURTADO S.en_GB
dc.contributor.authorKARFOPOULOS K. L.en_GB
dc.contributor.authorKLEMOLA S.en_GB
dc.contributor.authorKOVAR P.en_GB
dc.contributor.authorLEE K.b.en_GB
dc.contributor.authorOCONE R.en_GB
dc.contributor.authorOTT O.en_GB
dc.contributor.authorSIMA O.en_GB
dc.contributor.authorSUDAR S.en_GB
dc.contributor.authorSVEC Antonen_GB
dc.contributor.authorCHAU Van Taoen_GB
dc.contributor.authorTRAN Thien Thanhen_GB
dc.contributor.authorVIDMAR T.en_GB
dc.date.accessioned2012-04-17T19:52:24Z-
dc.date.available2010-06-17en_GB
dc.date.available2012-04-17T19:52:24Z-
dc.date.created2010-06-15en_GB
dc.date.issued2010en_GB
dc.date.submitted2010-06-01en_GB
dc.identifier.citationAPPLIED RADIATION AND ISOTOPES vol. 68 no. 7-8 p. 1407-1412en_GB
dc.identifier.issn0969-8043en_GB
dc.identifier.uriwww.elsevier.com/locate/apradisoen_GB
dc.identifier.urihttp://publications.jrc.ec.europa.eu/repository/handle/JRC58929-
dc.description.abstractA comparison of the coincidence summing correction methods is presented. Since there are several ways for computing these corrections, each method has advantages and drawbacks that could be compared. This part of the comparison was restricted to point sources. The same experimental spectra, decay scheme and photon emission intensities were used by all the participants. The results were expressed as coincidence summing correction factors for several energies of 152Eu and 134Cs, and three source-to-detector distances. They are presented and discussed.en_GB
dc.description.sponsorshipJRC.D.4-Nuclear physicsen_GB
dc.format.mediumPrinteden_GB
dc.languageENGen_GB
dc.publisherPERGAMON-ELSEVIER SCIENCE LTDen_GB
dc.relation.ispartofseriesJRC58929en_GB
dc.titleIntercomparison of Methods for Coincidence Summing Corrections in Gamma-Ray Spectrometryen_GB
dc.typeArticles in periodicals and booksen_GB
dc.identifier.doi10.1016/j.apradiso.2010.01.012en_GB
JRC Directorate:Health, Consumers and Reference Materials

Files in This Item:
There are no files associated with this item.


Items in repository are protected by copyright, with all rights reserved, unless otherwise indicated.