Full metadata record
DC FieldValueLanguage
dc.contributor.authorLINSINGER Thomasen_GB
dc.contributor.authorAUCLAIR Guyen_GB
dc.contributor.authorRAFFAELLI BARBARAen_GB
dc.contributor.authorLAMBERTY MARIE ANDREEen_GB
dc.contributor.authorGAWLIK Bernden_GB
dc.date.accessioned2012-12-06T01:02:22Z-
dc.date.available2012-12-05en_GB
dc.date.available2012-12-06T01:02:22Z-
dc.date.created2012-08-03en_GB
dc.date.issued2011en_GB
dc.date.submitted2010-09-24en_GB
dc.identifier.citationTRAC-TRENDS IN ANALYTICAL CHEMISTRY vol. 30 no. 6 p. 875-886en_GB
dc.identifier.issn0165-9936en_GB
dc.identifier.urihttp://publications.jrc.ec.europa.eu/repository/handle/JRC60786-
dc.description.abstractWe present results of the systematic stability monitoring of certified reference materials (CRMs) for the mass fractions of metal species. Materials are tested regularly for the mass fractions of organotin, organomercury, organolead and organoarsenic species. Evaluation is based on ratios of results on samples stored under normal conditions and under even safer conditions (‘‘reference stock’’) to eliminate the effects of laboratory-to-laboratory variation. Of all results in this study, the results of organotin measurements show the highest relative standard deviations (up to 45%). Determination of methylmercury in sediment and fish is possible with much better precision (standard deviations of reproducibility below 5%). The accuracies of determinations of trimethyllead and organoarsenic species are slightly worse but still below 10%. The data confirmed stability since production (i.e. up to 13 years). However, shelf lives cannot be extended into the future based on these data, as uncertainty contributions for stability need to be included in the uncertainty budgets of CRMs to allow positive demonstration of the validity of certificates. Estimation of typical measurement uncertainties based on the data obtained from stability monitoring shows that potential degradation is negligible compared to uncertainties typical for this kind of measurement, demonstrating that the materials are still sufficiently reliable to demonstrate laboratory proficiency.en_GB
dc.description.sponsorshipJRC.D.2-Reference materialsen_GB
dc.format.mediumPrinteden_GB
dc.languageENGen_GB
dc.publisherELSEVIER SCI LTDen_GB
dc.relation.ispartofseriesJRC60786en_GB
dc.titleConclusions from 13 years of stability testing of CRMs for determination of metal speciesen_GB
dc.typeArticles in periodicals and booksen_GB
dc.identifier.doi10.1016/j.trac.2011.01.015en_GB
JRC Directorate:Health, Consumers and Reference Materials

Files in This Item:
There are no files associated with this item.


Items in repository are protected by copyright, with all rights reserved, unless otherwise indicated.