Excess heat capacity in liquid binary alkali-fluoride mixtures
Using drop calorimetry we measured enthalpy increments of the LiF-KF, LiF-RbF and LiFCsF
binary systems at temperatures above melting. 10 samples with different compositions
(four compositions for LiF-KF, one composition for LiF-RbF and five compositions for LiFCsF)
were prepared and measured between 884K and 1382 K. To protect the calorimeter from
corrosive fluoride vapor at high temperature an encapsulating technique developed for this
purpose was used. The samples were filled in nickel containers which were sealed by laser
welding and afterwards used for the measurements. From the obtained results we derived the
molar heat capacity functions of the respective samples. The heat capacities of the samples,
having different compositions of the same binary system, were compared with the values for
ideal behavior and the excess heat capacity function was determined for the whole composition range of the liquid solution. It was found that the excess heat capacities clearly depend on the
cation radius and increases in the order LiF-NaF < LiF-KF < LiF-RbF < LiF-CsF.
BEILMANN Markus;
BENES Ondrej;
CAPELLI Elisa;
REUSCHER Vivien;
KONINGS Rudy;
FANGHAENEL Thomas;
2013-04-19
AMER CHEMICAL SOC
JRC73533
0020-1669,
http://pubs.acs.org/doi/abs/10.1021/ic302168g,
https://publications.jrc.ec.europa.eu/repository/handle/JRC73533,
10.1021/ic302168g,
Additional supporting files
| File name | Description | File type | |