Issues to be considered when measuring ultrasonic wave attenuation in austenitic cladding material
The experimental data obtained in a previous study is reprocessed to estimate the impact of several modifications of the measurement approach on the intrinsic longitudinal wave attenuation as a function of the propagation direction in reactor pressure vessel strip cladding. The measurement of the attenuation in anisotropic structures is a difficult task and this paper provides more insight on how the measurement approach works. It should help the reader to plan and carry out similar experiments.
SELDIS Thomas;
2013-05-02
BRITISH INST NON-DESTRUCTIVE TESTING
JRC77417
1354-2575,
http://www.bindt.org/Publications/Insight_Journal/This_month's_Insight.html,
https://publications.jrc.ec.europa.eu/repository/handle/JRC77417,