Half-life measurements of lutetium-176 using underground HPGe-detectors
The half-life of 176Lu was determined by measuring the 176Lu activity in metallic lutetium foils. Three different HPGe-detectors located 225 m underground were employed for the study. Measurements using the sum-peak method were performed and resulted in an average massic activity of 52.61±0.36 Bq•g-1. The foils were of natural isotopic abundance so using the massic activity and the value of the natural isotopic abundance of (2.59±0.01)%, a half-life of (3.722±0.029)x10^10a could be calculated.
HULT Mikael;
VIDMAR Tim;
ROSENGARD Christian Ulf;
MARISSENS Gerd;
LUTTER Guillaume;
SAHIN Namik;
2014-05-22
PERGAMON-ELSEVIER SCIENCE LTD
JRC82739
0969-8043,
http://www.sciencedirect.com/science/article/pii/S0969804313005204,
https://publications.jrc.ec.europa.eu/repository/handle/JRC82739,
10.1016/j.apradiso.2013.11.071,
Additional supporting files
| File name | Description | File type | |