Title: An Assessment on the Quantification of Hydrogen Releases through Oxygen Displacement Using Oxygen Sensors
Authors: BUTTNER WilliamBURGESS RobertRIVKIN CarlPOST MatthewBRETT LoisPALMISANO VALERIOMORETTO Pietro
Citation: 5th ICHS 2013
Publisher: HySafe
Publication Year: 2013
JRC N°: JRC83363
URI: http://www.ichs2013.com/index.php/papers-list
http://publications.jrc.ec.europa.eu/repository/handle/JRC83363
Type: Articles in periodicals and books
Abstract: Contrary to several reports in the recent literature, the use of oxygen sensors for indirectly monitoring ambient hydrogen concentration has serious drawbacks. This method is based on the assumption that a hydrogen release will displace oxygen, which is quantified using oxygen sensors. Despite its shortcomings, the draft Hydrogen Vehicle Global Technical Regulation lists this method as a means to monitor hydrogen leaks to verify vehicle fuel system integrity. Experimental evaluations that were designed to impartially compare the ability of commercial oxygen and hydrogen sensors to reliably measure and report hydrogen concentration changes are presented. Numerous drawbacks are identified and discussed.
JRC Directorate:Energy, Transport and Climate

Files in This Item:
There are no files associated with this item.