Full metadata record
DC FieldValueLanguage
dc.contributor.authorRICHTER Stephanen_GB
dc.contributor.authorKÜHN H.en_GB
dc.contributor.authorTRUYENS Janen_GB
dc.contributor.authorMIALLE SÉBASTIENen_GB
dc.contributor.authorAREGBE Yetundeen_GB
dc.date.accessioned2013-12-05T01:01:45Z-
dc.date.available2013-12-04en_GB
dc.date.available2013-12-05T01:01:45Z-
dc.date.created2013-11-29en_GB
dc.date.issued2013en_GB
dc.date.submitted2013-08-16en_GB
dc.identifier.citationINMM Annual Meeting Proceedings p. [6 pages]en_GB
dc.identifier.urihttp://www.inmm.org/Annual_Meeting_Proceedings/3995.htmen_GB
dc.identifier.urihttp://publications.jrc.ec.europa.eu/repository/handle/JRC83605-
dc.description.abstractFor UF6 mass spectrometry two types of "standards" are equally important: firstly "documentary standards" which describe specific measurement techniques and associated calculations, and secondly "material standards" which are preferentially SItraceable certified isotopic reference materials, as e.g. provided by the European Commission's Institute for Reference Materials and Measurements (IRMM). Recently the IRMM has upgraded its facilities for uranium isotopic measurements using uranium hexafluoride (UF6) gas by the acquisition of a new gas source mass spectrometer (GSMS), the "URANUS" from Thermo Fisher. By that IRMM has expanded its UF6 mass spectrometry capability from measurements of only the "major" isotope ratio n(235U)/n(238U) towards the so-called "minor" isotope ratios n(234U)/n(238U) and n(236U)/n(238U). The minor ratios contain increasingly valuable information about the source of the original ("feed") material used for the commercial or possibly clandestine isotopic enrichment of UF6 and have therefore reached a high level of attention for safeguards authorities. "Documentary standards": within the recent few years new measurement techniques for UF6-GSMS have been developed at IRMM, e.g. the "memory corrected double standard" (MCDS) technique which shows an improved measurement performance for both the "major" n(235U)/n(238U) isotope ratio as well as the "minor" isotope ratios n(234U)/n(238U) and n(236U)/n(238U). A careful revision of some of the documentary standards for UF6 GSMS measurements (e.g. ASTM C1429-99) is now strongly suggested by IRMM. This will be an important contribution to improve the overall performance of UF6 GSMS measurements. It is a good example of the JRC’s expertise contributing to standardization and innovation by further developing material standards and reference methods but also documentary standards to the benefit of the safeguards community and industry. "Material standards": IRMM has just started a comprehensive project for a new certification of the worldwide most widely used and well-known IRMM-019 to IRMM-029 series of 12 UF6 reference materials. Special emphasis will be given on achieving lower uncertainties particularly for the "minor" isotope ratios using previously established high performance TIMS instrumentation and techniques. This new certification is a prerequisite for achieving accurate results for UF6 GSMS measurements also for the minor ratios to be used for nuclear safeguards investigations.en_GB
dc.description.sponsorshipJRC.D.4-Standards for Nuclear Safety, Security and Safeguardsen_GB
dc.format.mediumOnlineen_GB
dc.languageENGen_GB
dc.publisherInstitute of Nuclear Materials Managementen_GB
dc.relation.ispartofseriesJRC83605en_GB
dc.titleStandards for uranium hexafluoride (UF6) mass spectrometryen_GB
dc.typeArticles in periodicals and booksen_GB
JRC Directorate:Health, Consumers and Reference Materials

Files in This Item:
There are no files associated with this item.


Items in repository are protected by copyright, with all rights reserved, unless otherwise indicated.