Microstructural analysis of thermal fatigue damage in 316L pipes
This report summarizes the data and main conclusions derived from microstructural characterisation of 316L pipes subjected to thermal fatigue with a peak temperature of 550°C. TOFD measurements are compared with measured crack depths from cut segments, and fracture mode and corrosion have been assessed by SEM and EDX, respectively.
GONZALEZ SANCHEZ Sergio;
RUIZ MORENO Ana Maria;
NILSSON Karl-Fredrik;
2014-01-14
Publications Office of the European Union
JRC87415
978-92-79-35100-6,
1831-9424,
EUR 26445,
OP LD-NA-26445-EN-N,
https://publications.jrc.ec.europa.eu/repository/handle/JRC87415,
10.2790/12330,
Additional supporting files
| File name | Description | File type | |