Within the framework of the European JASMIN project, the ASTEC-Na code is being developed for safety analysis of severe accidents in SFR. In the first phase of validation of the ASTEC-Na fuel thermo-mechanical models three in-pile tests conducted in the CABRI experimental reactor have been selected to be analysed. We present here the preliminary results of the simulation of two Transient Over Power tests and one power ramp test (AGS0, LT2 and E9, respectively) where no pin failure occurred during the transient. We present the comparison of ASTEC-Na results against experimental data and other safety code results for the initial steady state conditions prior to the transient onset as well as for the fuel pin behaviour during the transients.
PEREZ-MARTIN S.;
BANDINI G.;
MATUZAS Vaidas;
BUCK M.;
GIRAULT N.;
2015-07-09
JSME
JRC95116
https://publications.jrc.ec.europa.eu/repository/handle/JRC95116,
| Name | Country | City | Type |
|---|
This document is only visible at the Commission level.
You are not authorized to publish or distribute it outside the European Commission.
This is a public document. You can share this publication.
Datasets
| ID | Title | Public URL |
|---|
Dataset collections
| ID | Acronym | Title | Public URL |
|---|
Scripts / source codes
| Description | Public URL |
|---|
Additional supporting files
| File name | Description | File type |
|---|