Title: Erratum to “CFD analysis of fast filling strategies for hydrogen tanks and their effects on key-parameters” [Int J Hydrogen Energy 40 (2015) 735-745]
Authors: MELIDEO DANIELEBARALDI Daniele
Citation: INTERNATIONAL JOURNAL OF HYDROGEN ENERGY vol. 40 no. 18 p. 6260–6268
Publisher: PERGAMON-ELSEVIER SCIENCE LTD
Publication Year: 2015
JRC N°: JRC95198
ISSN: 0360-3199
URI: http://www.sciencedirect.com/science/article/pii/S0360319915005273#
http://publications.jrc.ec.europa.eu/repository/handle/JRC95198
DOI: 10.1016/j.ijhydene.2015.02.125
Type: Articles in periodicals and books
Abstract: A major requirement for the filling of hydrogen tanks is the maximum gas temperature within the vessels during the process. Different filling strategies in terms of pressure and temperature of the gas injected into the cylinder and their effects on key parameters like maximum temperature, state of charge, and energy cooling demand are investigated. It is shown that pre-cooling of the gas is required but is not necessary for the whole duration of the filling. Relevant energy savings can be achieved with pre-cooling over a fraction of the time. The most convenient filling strategy from the cooling energy point of view is identified: with an almost linear pressure rise and pre-cooling in the second half of the process, a 60% reduction of the cooling energy demand is achieved compared to the case of precooling for the whole filling.
JRC Directorate:Energy, Transport and Climate

Files in This Item:
There are no files associated with this item.


Items in repository are protected by copyright, with all rights reserved, unless otherwise indicated.