The certification of the absorbed energy (120 J nominal) of Charpy V-notch reference test pieces for tests at 20 °C: ERM®-FA016bj
This certification report describes the processing and characterisation of ERM®-FA016bj, a batch of Charpy V-notch certified reference test pieces certified for the absorbed energy KV (= energy required to break a V-notched test piece using a pendulum impact test machine). Sets of five of these test pieces are used for the verification of pendulum impact test machines according to ISO 148-2 (Metallic materials - Charpy pendulum impact test – Part 2: Verification of testing machines).
The absorbed energy (KV) is operationally defined and refers to the impact energy required to break a V-notched test piece of standardised dimensions, as defined in ISO 148-1. The certified value of ERM®- FA016bj is made traceable to the SI, via the SI-traceable certified value of the master batch ERM®-FA016ax, by testing samples of ERM®- FA016bj and ERM®-FA016ax under repeatability conditions on an impact pendulum verified and calibrated with SI-traceably calibrated tools. The certified value is valid only for strikers with a 2 mm tip radius. The certified value is valid at (20 ± 2) °C.
GERGANOVA Tsvetelina Ivanova;
ROEBBEN Gert;
DEAN Alan;
LINSINGER Thomas;
2016-02-05
Publications Office of the European Union
JRC98494
978-92-79-53885-8,
1831-9424,
EUR 27580,
OP LA-NA-27580-EN-N,
https://publications.jrc.ec.europa.eu/repository/handle/JRC98494,
10.2787/18570,
Additional supporting files
| File name | Description | File type | |